HK SC

Sequence valve

Sequence valve

Fabrication
à pilotage direct 
atmospherically relieved 
with bypass non-return valve 
Pression de service max.
350 bar
Customs tariff number
84812010 
Téléchargement du PDF

Veuillez saisir une exécution

Show table of articles
Register now to get access to our online shop

Register now and access our complete product range and many exclusive services.

Caractéristiques

Fabrication
  • à pilotage direct 
  • atmospherically relieved 
  • with bypass non-return valve 
Pression de service max.
  • 350 bar
Customs tariff number
  • 84812010 

Product description

Remarques
Ces vannes doivent être ajustés en fonction de l'utilisation prévue.
Description
These valves enable the flow to be switched to a second circuit as soon as the pressure at port 1 exceeds the set value for the valve.
In addition, a reverse flow from port 2 to port 1 is possible via the integrated check valve.
The pressure setting regulates the pressure at port 1 depending on the atmospheric relief.
Atmospherically relieved valves should only be used if it is not possible to create a drain port.
Over time, these valves can leak externally or moisture can get into the spring chamber.

Gamme de produits

2 Résultats
Afficher le plan coté
Désignation
Plage de réglage min. (bar)
Plage de réglage maxi (bar)
A (mm)
B (mm)

Column selection

Plage de réglage min. (bar)
Plage de réglage maxi (bar)
A (mm)
B (mm)
SW (mm)
Débit volumique maxi (l/min)
Boîtier vissé
Filet vissé
Filet vissé