Engine
24 V DC
Power
2.2 kW
Operating mode
S2: 1.2 min; S3: 4.5 %
Veuillez saisir une exécution
Enregistrez-vous maintenant pour accéder à notre boutique en ligne.
Register now and access our complete product range and many exclusive services.
Détails produit concernant
HKK 24V 2.2-210 6 5
Engine
24 V DC
Power
2.2 kW
Operating mode
S2: 1.2 min; S3: 4.5 %
Pressure max.
210 bar
Nominal pressure
190 bar
Nominal volume current
6 l/min
Tank size
5 l
A
433 mm
B
190 mm
C
238 mm
Toutes les caractéristiques
Caractéristiques
Design
- Basic unit with direct current motor, without control valve
Media
- Hydraulic fluids based on mineral oil
Connection P + T
- BSPP female thread, parallel
Thread P + T
- G 1/4″ -19
Customs tariff number
- 84136020
Toutes les caractéristiques
Description du produit
Remarques
Additional components such as control valves can be retrofitted if required.
Description
Tested and set to maximum operating pressure.
Adjustable pressure relief valve.
Non-return valve in channel P.
Without control valves.
These units can be used horizontally and vertically.
The usable volume of the tank depends on the installation position.
Tank size 5 liters: usable volume horizontal 4.0 liters, vertical 3.0 liters.
Tank size 8 liters: usable volume horizontal 6.6 liters, vertical 5.8 liters.
Contenu de la livraison
Gamme de produits
5 Résultats
Recherche
Afficher le plan coté
Désignation
12 V DC
0,8 kW
S2: 4 min; S3: 9 %
180 bar
12 V DC
1,6 kW
S2: 3 min; S3: 7.5 %
210 bar
24 V DC
0,8 kW
S2: 4 min; S3: 10 %
180 bar
24 V DC
2,2 kW
S2: 1.2 min; S3: 4.5 %
210 bar
24 V DC
3 kW
S2: 4 min; S3: 15 %
230 bar
Operating mode: S2 - short-term operation, S3 - periodic operation
Max. pressure: Maximum operating pressure, set value of the pressure relief valve
The values for the nominal volumetric flow rate are valid at the maximum pressure stated in the table
Column selection
Moteur
Puissance (kW)
Fonction
Pression maxi (bar)
Pression de service max. (bar)
Débit volumétrique nominal (l/min)
Volume (l)
A (mm)
B (mm)
C (mm)
Operating mode: S2 - short-term operation, S3 - periodic operation
Max. pressure: Maximum operating pressure, set value of the pressure relief valve
The values for the nominal volumetric flow rate are valid at the maximum pressure stated in the table